SMC GEN1 EBOX - 1U12Drive

Prev Next

Product Name: SMC EBOX GEN1 (SMC)

Configurations


Model

Drive Config

SCM

QLC/TLC

AS-1115HS-TNR-OTO-66

3x 800GB SCM +9x 15TB QLC

Kioxia FL6 or TBC

TBC

AS-1115HS-TNR-OTO-66

3x 1.6TB SCM +9x 30TB QLC

Kioxia FL6 or TBC

Micron 6500 ION

AS-1115HS-TNR-OTO-66

3x 1.6TB SCM +9x 60TB QLC

Kioxia FL6 or TBC

TBC

Specification


Chassis

Nodes:

  • 1 x 1U Single Server Node

  • Super Micro MPN AS-1115HS-TNR-OTO-66 Supermicro,1U,Genoa,L8

I/O Connectivity:

  • 4x 200GbE/NDR200 IB

Management (optional): 

  • 4 x 1GbE Ports, OCP, Intel i350

Power Supplies:

  • 2x 1200W Redundant Titanium Level (96%) power supplies

AC POWER

  • Nominal Input Range:

    1200 W: 200-240 Vac / 7.5 A-6 A / 50-60 Hz
    1200 W: 230-240Vdc / 50-60Hz (for CCC only)

  • Inrush current:

  • Maximum system continuous DC output power rating: +12V Max: 100 A / Min: 0 A (200 Vac-240 Vac)

Per Node

CPU:

  • AMD EPYC 9454P 48-Core Processor (Codename “Genoa”)

Memory:

  • 384GB (12 x 32GB) DDR5-4800

NIC:

  • 2x Mellanox CX7 Dual Port MCX755106AS-HEAT

Boot Drive:

  • 2 x 960Gb NVMe U.2 SAMSUNG MZQL2960HCJR-00A07

Environmental Data

Dimensions:

  • Rack Units: 1U

  • Width: 19” Rack - 17.2" (437 mm)

  • Height: 1.7" (43 mm)

  • Depth: 29.4" (747 mm)

  • Package 8.1" (H) x 23.8" (W) x 40.6" (D)

Weight with drives: 

  • Gross Weight: 51 lbs (23.1 kg)

  • Net Weight: 32 lbs (14.5 kg)

Acoustics (declared sound power):

  • TBC

Airflow

  • TBC

Power Consumption:

  • Active: 700W

  • Max: 900W

Operating Environment:

  • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)

  • Operating Relative Humidity: 8% to 90% (non-condensing)

Non-Operating Environment:

  • Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)

  • Non-operating Relative Humidity: 5% to 95% (non-condensing)

Certifications


Regulatory Compliance

  • FCC

  • ICES

  • CE

  • VCCI

  • RCM

  • UKCA

  • NRTL

  • CB

Electromagnetic Emissions & Immunity Standards

  • 2014/30/EU (EMC Directive)

  • Electromagnetic Compatibility Regulations 2016

  • FCC Part 15 Subpart B

  • ICES-003

  • VCCI-CISPR 32

  • AS/NZS CISPR 32

  • BS/EN55032

  • BS/EN55035

  • BS/EN 61000-3-2

  • BS/EN 61000-3-3

  • BS/EN 61000-4-2

  • BS/EN 61000-4-3

  • BS/EN 61000-4-4

  • BS/EN 61000-4-5

  • BS/EN 61000-4-6

  • BS/EN 61000-4-8

  • BS/EN 61000-4-11

Green/Environmental

  • 2011/65/EU (RoHS Directive)

  • EC 1907/2006 (REACH)

  • 2012/19/EU (WEEE Directive)

  • California Proposition 65

Safety Standards

  • 2014/35/EU (LVD Directive)

  • Electrical Equipment (Safety) Regulations 2016

  • UL/CSA 62368-1 (USA and Canada)

  • BS/IEC/EN 62368-1

TAA Certification

Manufacturer Documentation


https://www.supermicro.com/en/products/system/hyper/1u/as-1115hs-tnr

https://www.supermicro.com/manuals/superserver/1U/MNL-2607.pdf

https://www.supermicro.com/manuals/superserver/1U/Lot9_AS-1115HS-TNR.pdf

Product Images


Front:

The image illustrates a server with labeled components, including the power button, status LEDs, UID button, and one USB port, providing visual guidance on locating these critical features for system management and maintenance purposes.

Back:

The image illustrates the rear panel of a server, highlighting components such as PSU 1 and PSU 2, PCIe Slot 1 (Bus 01h) with Port 1 labeled BMC beneath it, AIOM (Bus C1h), and PCIe Slot Port 2 on Bus 81h, providing a detailed view useful for assembly or troubleshooting purposes.

Side:

The image depicts an open server chassis housing multiple CPU blades and interconnected components, showcasing its modular design suited for high-performance computing environments. The intricate internal architecture highlights the complexity and scalability typical in enterprise-grade servers.