The Green Port - the leftmost RJ45 on the Cascade Lake CNode (The Green Port) is “reserved” and is not used in a VAST Deployment.

⚠️ Warning

Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.

ℹ️ Note

Skip NIC cannot be used with multi-homed configurations.

Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with IB+ETH Multi-homed

Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with IB+ETH Multi-homed

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Internal

5e:00.0

8

enp94s0f1

Right Card – Right Port

Internal

5e:00.1

9

ib0

Left NIC - Left Port

Northbound / Split

3b:00.1

10

enp59s0f0

Left NIC - Right Port

Northbound / Split

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with ETH+IB Multi-homed

Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with ETH+IB Multi-homed

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Internal

5e:00.0

8

enp94s0f1

Right Card – Right Port

Internal

5e:00.1

9

enp59s0f1

Left NIC - Left Port

Northbound / Split

3b:00.1

10

ib0

Left NIC - Right Port

Northbound / Split

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with IB + ETH Multi-homed

Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with IB + ETH Multi-homed

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

ib0

Right Card – Left Port

Internal

5e:00.0

8

ib1

Right Card – Right Port

Internal

5e:00.1

9

ib0

Left NIC - Left Port

Northbound / Split

3b:00.1

10

enp59s0f0

Left NIC - Right Port

Northbound / Split

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with ETH + IB Multi-homed

Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in IB mode with ETH + IB Multi-homed

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

ib0

Right Card – Left Port

Internal

5e:00.0

8

ib1

Right Card – Right Port

Internal

5e:00.1

9

enp59s0f1

Left NIC - Left Port

Northbound / Split

3b:00.1

10

ib0

Left NIC - Right Port

Northbound / Split

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).

ℹ️ Note

Using the Reverse NIC functionality together with Multi-home is supported, but has extremely limited use cases.  Thus it is not documented here.