CL Port Diagrams - Ethernet

Prev Next

ℹ️ Info

The Green Port - the leftmost RJ45 on the Cascade Lake CNode (The Green Port) is “reserved” and is not used in a VAST Deployment.

⚠️ Warning

Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.

Cascade Lake CBox with single CX5 NIC in Ethernet Mode

The Images shows the rear view of a server with the ports labeled by number.

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Unified

5e:00.0

8

enp94s0f1

Right Card – Right Port

Unified

5e:00.1

9

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

10

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH + ETH mode

The Images shows the rear view of a server with the ports labeled by number.

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Internal

5e:00.0

8

enp94s0f1

Right Card – Right Port

Internal

5e:00.1

9

enp59s0f1

Left NIC - Left Port

Northbound / Split

3b:00.1

10

enp59s0f0

Left NIC - Right Port

Northbound / Split

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with Dual CX5 or CX5+CX6 NIC in ETH mode with “Skip NIC - External” enabled

ℹ️ Info

The “Skip NIC - External” flag is a setting that can be set either in the VAST GUI Installer or via the command line configure_network.py tool.  This flag is set on a per-CNode basis.

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

When this flag is used, VAST instructs the auto-ports feature to disable the NIC that is typically designated for northbound traffic.  This means that if you use this flag on a node with two NICs, the NIC designated for internal traffic will handle both internal and external (aka Unified) network traffic. This means the network interfaces that would typically be solely used for northbound connections are effectively disabled. This flag is not valid on a single NIC CNode.

The Images shows the rear view of a server with the ports labeled by number.

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Unified

5e:00.0

8

enp94s0f1

Right Card – Right Port

Unified

5e:00.1

9

enp59s0f1

Left NIC - Left Port

Disabled

3b:00.1

10

enp59s0f0

Left NIC - Right Port

Disabled

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with CX5+CX6 NIC in ETH mode with “Skip NIC - Internal” enabled

ℹ️ Info

The “Skip NIC - Internal” flag is a setting that can be set either in the VAST GUI Installer or via the command line configure_network.py tool.  This flag is set on a per-CNode basis.

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

When this flag is used, VAST instructs the auto-ports feature to disable the NIC that is typically designated for internal traffic.  This means that if you use this flag on a node with two NICs, the NIC designated for northbound traffic will handle both internal and external (aka Unified) network traffic. This means the network interfaces that would typically be solely used for internal connections are effectively disabled. This flag is not valid on a single NIC CNode.

The Images shows the rear view of a server with the ports labeled by number.

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Disabled

5e:00.0

8

enp94s0f1

Right Card – Right Port

Disabled

5e:00.1

9

enp59s0f1

Left NIC - Left Port

Unified

3b:00.1

10

enp59s0f0

Left NIC - Right Port

Unified

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


Cascade Lake CBox with CX5+CX6 NIC in ETH + ETH mode with “Reverse NICs” enabled

ℹ️ Info

The “Reverse NICs” flag is a setting that can be set either in the VAST GUI Installer or via the command line configure_network.py tool.  This flag is set on a per-CNode basis.

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

The “Reverse NICs” flag refers to a specific configuration that swaps the roles between the NIC  intended for northband traffic and the NIC intended for internal traffic. This is primarily used in scenarios where the physical cabling or hardware layout necessitates a reversal of these roles.

The Images shows the rear view of a server with the ports labeled by number.

Cascade Lake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

enp94s0f0

Right Card – Left Port

Northbound/Split

5e:00.0

8

enp94s0f1

Right Card – Right Port

Northbound/Split

5e:00.1

9

enp59s0f1

Left NIC - Left Port

Internal

3b:00.1

10

enp59s0f0

Left NIC - Right Port

Internal

3b:00.0

11

eno1

1 GbE Port 1 (Left)

MGMT/IPMI (*TECH)

12

eno2

1 GbE Port 2 (Right)

TECH (*MGMT)

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (eno2) and the TECH port is moved to 1GbE port 1 (eno1).


ℹ️ Note