xFusion GEN1 EBOX - 1U10Drive

Prev Next

Configurations


Model

Drive Config

SCM

TLC/QLC

xFusion GEN1 EBox - 122TB (15TB QLC)

2x 800GB SCM + 8x 15TB QLC

2 x Solidigm P5810 (800GB)

7 x Solidigm P5316 (15.36TB)

xFusion GEN1 EBox - 107TB (15TB QLC)

3x 800GB SCM + 7x 15TB QLC

2 x Solidigm P5810 (800GB)

8 x Solidigm P5316 (15.36TB)

Specification


Chassis

Node:

  • xFusion FusionServer 1158 V7

  • 1 x 1U 10 Drive, Single Server Node

I/O Connectivity:

  • 4x 200GbE/NDR200 IB 

Management (optional): 

  • 4 x 1GbE Ports, OCP, Intel i350

Power Supplies:

  • 2× 900W Redundant Titanium Level (96%) power supplies

AC POWER

  • Nominal Input Range:

  • 900 W: 200-240 Vac / 6.47 A-5.84 A / 50-60 Hz
    900 W: 230-240Vdc / 50-60Hz (for CCC only)

  • Max Inrush current (A peak): 20 

  • Max Inrush Current (ms): 0.2

  • Maximum system continuous DC output power rating: +12V Max: 100 A / Min: 0 A (200 Vac-240 Vac)

  • Minimum Rated Power Factor: 0.97

CPU:

  • AMD EPYC 9454P 48-Core Processor (Codename “Genoa”)

Memory:

  • 384GB (12 x 32GB) DDR5-4800

NIC:

  • 2 x Bluefield3 SuperNIC B3220L (2x200G), model 900-9D3B4-00SV-EA

Management NIC

  • 2 x 10GbE Ports, Cisco Systems Inc Ethernet Network Adapter X710-T2L OCP 3.0 (Intel OEM)

Boot Drive:

  • 2 x 1TB SATA (RAID 1)

Environmental Data

Dimensions:

  • Rack Units: 1U

  • Width: 19” Rack - 17.15" (435.6 mm)

  • Height: 1.7" (43 mm)

  • Depth: 31.42" (798 mm)

Weight with drives: 

  • Gross Weight: (Including Drives)

  • Net Weight: 38.58 lbs (17.5 kg)

Acoustics (declared sound power):

  • Idle:

            LWAd: 5.75 Bels

            LpAm: 47.3 dBA

  • Operating:

            LWAd: 6.69 Bels

            LpAm: 56.0 dBA

Airflow:

≥96CFM

Power Consumption:

  • Idle: TBC

  • Active: 700W, (Estimated)

  • Max: 900W, (Estimated)

Input Connector:

  • 2x IEC320 C14

Operating Environment:

  • Operating Temperature: 5°C ~ 45°C (41°F ~ 113°F)

  • Operating Relative Humidity: 8% to 90% RH (non-condensing)

  • Altitude: 3050 Meters (10,006 ft)

Non-Operating Environment:

  • Non-operating Temperature: -40°C to 70°C (-40°F to 158°F)

  • Non-operating Relative Humidity: 5% to 95% RHH (non-condensing)

  • Altitude: 0-12,000 Meters (39,370 ft)

 Certifications


Regulatory Compliance:

  • Products should comply with CE Markings per the directives
    2014/30/EU and 2014/35/EU

Electromagnetic Emissions & Immunity Standards:

  • 47CFR Part 15 (CFR 47) Class A

  • AS/NZS CISPR32 Class A

  • CISPR32 Class A

  • EN55032 Class A

  • ICES003 Class A

  • VCCI-CISPR32 Class A

  • EN61000-3-2

  • EN61000-3-3

  • KS C 9832 Class A

  • EN 300386 Class A

  • EN55035

  • EN55024

  • CISPR24/35

  • EN300386

  • KS C 9835

  • IEC/EN61000-6-1

Safety Standards:

  • UL 60950-1/62368-1

  • CAN/CSA-C22.2 No. 60950-1/62368-1

  • IEC/EN 60950-1/62368-1

  • AS/NZS 62368.1

  • GB 4943.1-2022

  • CNS 15598-1:2020

TAA Certification

 

Manufacturer BOM


NICS

  NVIDIA MCX755106AS-HEAT ConnectX-7 Adapter Card 200GbE/NDR200 Crypto Disabled

2

Drive Option - 1 - (Vast Release 5.5)

800GB Solidigm P5810 SCM Drive

2

15TB Intel P5316 QLC Drive

8

Drive Option - 2 - (Vast Release 5.5)

800GB Solidigm P5810 SCM Drive

3

15TB Intel P5316 QLC Drive

7

Manufacturers Documentation


System Data Sheet: FusionServer 1158H v7 Server Data Sheet

Quick Start Guide: xFusion Quick Start Guide

Server User Guide: FusionServer 1158H V7 Server User Guide 07

Product Images


Front:

A server rack displaying multiple drive bays and status indicators for monitoring.

Back:

Back panel of a device showing ports, slots, and power supply connections.

Power


Wattage

Frequency

Voltage/Current

Class

Heat dissipation

900 W mixed mode

50/60 Hz

00–240 V AC/ xxx A

Titanium

xxxx BTU/hr