HPE IL Port Diagrams - Mixed Ethernet + IB

Prev Next

ℹ️ Info

The HPE IceLake platform “flips” the left side (facing rear of unit) nodes.  VAST maps the locations of the High Speed ports in our software. Please pay careful attention to the management ports as they are mirrored left to right.

⚠️ Warning

Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.

HPE IceLake CBox with Dual CX6 or CX6+CX7 NIC in ETH + IB mode

HPE IceLake CBox with Dual CX6 or CX6+CX7

HPE IceLake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

ib1

Nodes 1+2 (Right Side) Left Card – Left Port

Northbound/Split

63:00.1

8

ib0

Nodes 1+2 (Right Side) Left Card – Right Port

Northbound/Split

63:00.0

9

ens1f0

Nodes 3+4 (Left Side) Right Card – Left Port

Internal

63:00.0

10

ens1f1

Nodes 3+4 (Left Side) Right Card – Right Port

Internal

63:00.1

11

ens2f0

Nodes 1+2 (Right Side) Right Card – Left Port

Internal

84:00.0

12

ens2f1

Nodes 1+2 (Right Side) Right Card – Right Port

Internal

84:00.1

13

ib1

Nodes 3+4 (Left Side) Left Card – Left Port

Northbound/Split

84:00.1

14

ib0

Nodes 3+4 (Left Side) Left Card – Right Port

Northbound/Split

84:00.0

15

ens8f0

1GbE Port 1 (Closest to PSU)

MGMT/IPMI

16

ens8f1

1GbE Port 2

(*MGMT)

17

ens8f4

1GbE Port 4 (Outermost)

TECH

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).


HPE IceLake CBox with Dual CX6 or CX6+CX7 NIC in IB + ETH mode

HPE IceLake CBox with Dual CX6 or CX6+CX7

HPE IceLake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

ens1f1

Nodes 1+2 (Right Side) Left Card – Left Port

Northbound/Split

63:00.1

8

ens1f0

Nodes 1+2 (Right Side) Left Card – Right Port

Northbound/Split

63:00.0

9

ib0

Nodes 3+4 (Left Side) Right Card – Left Port

Internal

63:00.0

10

ib1

Nodes 3+4 (Left Side) Right Card – Right Port

Internal

63:00.1

11

ib0

Nodes 1+2 (Right Side) Right Card – Left Port

Internal

84:00.0

12

ib1

Nodes 1+2 (Right Side) Right Card – Right Port

Internal

84:00.1

13

ens2f1

Nodes 3+4 (Left Side) Left Card – Left Port

Northbound/Split

84:00.1

14

ens2f0

Nodes 3+4 (Left Side) Left Card – Right Port

Northbound/Split

84:00.0

15

ens8f0

1GbE Port 1 (Closest to PSU)

MGMT/IPMI

16

ens8f1

1GbE Port 2

(*MGMT)

17

ens8f4

1GbE Port 4 (Outermost)

TECH

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).


ℹ️ Note

The HPE IceLake Platform does not support the Reverse NICs option.