ℹ️ Info
The HPE IceLake platform “flips” the left side (facing rear of unit) nodes. VAST maps the locations of the High Speed ports in our software. Please pay careful attention to the management ports as they are mirrored left to right.
⚠️ Warning
Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.
HPE IceLake CBox with Dual CX6 or CX6+CX7 NIC in ETH + IB mode

HPE IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | ib1 | Nodes 1+2 (Right Side) Left Card – Left Port | Northbound/Split |
|
8 | ib0 | Nodes 1+2 (Right Side) Left Card – Right Port | Northbound/Split |
|
9 | ens1f0 | Nodes 3+4 (Left Side) Right Card – Left Port | Internal |
|
10 | ens1f1 | Nodes 3+4 (Left Side) Right Card – Right Port | Internal |
|
11 | ens2f0 | Nodes 1+2 (Right Side) Right Card – Left Port | Internal |
|
12 | ens2f1 | Nodes 1+2 (Right Side) Right Card – Right Port | Internal |
|
13 | ib1 | Nodes 3+4 (Left Side) Left Card – Left Port | Northbound/Split |
|
14 | ib0 | Nodes 3+4 (Left Side) Left Card – Right Port | Northbound/Split |
|
15 | ens8f0 | 1GbE Port 1 (Closest to PSU) | MGMT/IPMI | |
16 | ens8f1 | 1GbE Port 2 | (*MGMT) | |
17 | ens8f4 | 1GbE Port 4 (Outermost) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).
HPE IceLake CBox with Dual CX6 or CX6+CX7 NIC in IB + ETH mode

HPE IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | ens1f1 | Nodes 1+2 (Right Side) Left Card – Left Port | Northbound/Split |
|
8 | ens1f0 | Nodes 1+2 (Right Side) Left Card – Right Port | Northbound/Split |
|
9 | ib0 | Nodes 3+4 (Left Side) Right Card – Left Port | Internal |
|
10 | ib1 | Nodes 3+4 (Left Side) Right Card – Right Port | Internal |
|
11 | ib0 | Nodes 1+2 (Right Side) Right Card – Left Port | Internal |
|
12 | ib1 | Nodes 1+2 (Right Side) Right Card – Right Port | Internal |
|
13 | ens2f1 | Nodes 3+4 (Left Side) Left Card – Left Port | Northbound/Split |
|
14 | ens2f0 | Nodes 3+4 (Left Side) Left Card – Right Port | Northbound/Split |
|
15 | ens8f0 | 1GbE Port 1 (Closest to PSU) | MGMT/IPMI | |
16 | ens8f1 | 1GbE Port 2 | (*MGMT) | |
17 | ens8f4 | 1GbE Port 4 (Outermost) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).
ℹ️ Note
The HPE IceLake Platform does not support the Reverse NICs option.