HPE Gen5 Genoa Port Diagrams - Mixed Ethernet + InfiniBand

Prev Next

⚠️ Warning

Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.

ℹ️ Note

Skip NIC cannot be used with mixed Ethernet + IB configurations.

HPE Gen5 Genoa CBox with Dual CX7 NIC in ETH + IB mode

1ef755e3-8e4e-4b76-9ad8-1f9a3c6b86d4.png

HPE Gen5 Genoa CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

PSU 1

2

PSU 2

3

enp7s0f0

Right Card – Left Port

Internal

07:00.0

4

enp7s0f1

Right Card – Right Port

Internal

07:00.1

5

ib0

Left Card – Left Port

Northbound/Split

86:00.0

6

ib1

Left Card – Right Port

Northbound/Split

86:00.1

7

BMC

Dedicated BMC port

(*IPMI)

8

enp200s0f0

1 GbE Port 1 (Left)

MGMT/IPMI

c8:00.0

9

enp200s0f1

1 GbE Port 2

 (*MGMT)

c8:00.1

10

enp200s0f3

1 GbE Port 4 (Right)

TECH

c8:00.3

*In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp200s0f1), and port 1 (enp200s0f0) is connected  to the Dedicated BMC Port of the Peer Node


HPE Gen5 Genoa CBox with Dual CX7 NIC in IB + ETH mode

e954c54a-779e-41dc-8871-6a445ebdf848.png

HPE Gen5 Genoa CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

PSU 1

2

PSU 2

3

ib0

Right Card – Left Port

Internal

07:00.0

4

ib1

Right Card – Right Port

Internal

07:00.1

5

enp134s0f0

Left Card – Left Port

Northbound/Split

86:00.0

6

enp134s0f1

Left Card – Right Port

Northbound/Split

86:00.1

7

BMC

Dedicated BMC port

(*IPMI)

8

enp200s0f0

1 GbE Port 1 (Left)

MGMT/IPMI

c8:00.0

9

enp200s0f1

1 GbE Port 2

 (*MGMT)

c8:00.1

10

enp200s0f3

1 GbE Port 4 (Right)

TECH

c8:00.3

*In B2B IPMI configuration, the MGMT port is moved to 1GbE port 2 (enp200s0f1), and port 1 (enp200s0f0) is connected  to the Dedicated BMC Port of the Peer Node


ℹ️ Note

The Reverse NICs option is not used when mixing ETH + IB.