⚠️ Warning
Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.
ℹ️ Note
Skip NIC cannot be used with multi-homed configurations.
Dell IceLake CBox with dual CX6 NIC in ETH mode, Multi-homed ETH + IB
⚠️ Warning
Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | p2p2 | Right Card – Left Port | Internal | 31:00.1 |
8 | p2p1 | Right Card – Right Port | Internal | 31:00.0 |
9 | p1p2 | Left Card – Left Port | Northbound / Split | 17:00.1 |
10 | ib0 | Left Card – Right Port | Northbound / Split | 17:00.0 |
11 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
12 | em3 | 1 GbE Port 2 | (*MGMT) | |
13 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).
Dell IceLake CBox with dual CX6 NIC in ETH mode, Multi-homed IB + ETH
⚠️ Warning
Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox | ||||
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | p2p2 | Right Card – Left Port | Internal | 31:00.1 |
8 | p2p1 | Right Card – Right Port | Internal | 31:00.0 |
9 | ib0 | Left Card – Left Port | Northbound / Split | 17:00.1 |
10 | p1p1 | Left Card – Right Port | Northbound / Split | 17:00.0 |
11 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
12 | em3 | 1 GbE Port 2 | (*MGMT) | |
13 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).
Dell IceLake CBox with dual CX6 NIC in IB mode, Multi-homed IB + ETH
⚠️ Warning
Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | ib2 | Right Card – Left Port | Internal | 31:00.1 |
8 | ib1 | Right Card – Right Port | Internal | 31:00.0 |
9 | ib0 | Left Card – Left Port | Northbound / Split | 17:00.1 |
10 | p1p1 | Left Card – Right Port | Northbound / Split | 17:00.0 |
11 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
12 | em3 | 1 GbE Port 2 | (*MGMT) | |
13 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).
Dell IceLake CBox with dual CX6 or CX6 + CX7 NIC in IB mode, Multi-homed ETH + IB
⚠️ Warning
Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | ib2 | Right Card – Left Port | Internal | 31:00.1 |
8 | ib1 | Right Card – Right Port | Internal | 31:00.0 |
9 | p1p2 | Left Card – Left Port | Northbound / Split | 17:00.1 |
10 | ib0 | Left Card – Right Port | Northbound / Split | 17:00.0 |
11 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
12 | em3 | 1 GbE Port 2 | (*MGMT) | |
13 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).
ℹ️ Note
Using the Reverse NIC functionality together with Multi-home is supported, but has extremely limited use cases. Thus it is not documented here.