Dell IL Port Diagrams - Multi-Homed

Prev Next

⚠️ Warning

Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.

ℹ️ Note

Skip NIC cannot be used with multi-homed configurations.

Dell IceLake CBox with dual CX6 NIC in ETH mode, Multi-homed ETH + IB

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox with dual CX6 NIC in ETH

Dell IceLake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

p2p2

Right Card – Left Port

Internal

31:00.1

8

p2p1

Right Card – Right Port

Internal

31:00.0

9

p1p2

Left Card – Left Port

Northbound / Split

17:00.1

10

ib0

Left Card – Right Port

Northbound / Split

17:00.0

11

em2

1 GbE Port 1 (Left)

MGMT/IPMI

12

em3

1 GbE Port 2

 (*MGMT)

13

em5

1 GbE Port 4 (Right)

TECH

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).


Dell IceLake CBox with dual CX6 NIC in ETH mode, Multi-homed IB + ETH

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox with dual CX6 NIC in ETH mode

Dell IceLake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

p2p2

Right Card – Left Port

Internal

31:00.1

8

p2p1

Right Card – Right Port

Internal

31:00.0

9

ib0

Left Card – Left Port

Northbound / Split

17:00.1

10

p1p1

Left Card – Right Port

Northbound / Split

17:00.0

11

em2

1 GbE Port 1 (Left)

MGMT/IPMI

12

em3

1 GbE Port 2

 (*MGMT)

13

em5

1 GbE Port 4 (Right)

TECH

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).


Dell IceLake CBox with dual CX6 NIC in IB mode, Multi-homed IB + ETH

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox with dual CX6 NIC in IB mode

Dell IceLake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

ib2

Right Card – Left Port

Internal

31:00.1

8

ib1

Right Card – Right Port

Internal

31:00.0

9

ib0

Left Card – Left Port

Northbound / Split

17:00.1

10

p1p1

Left Card – Right Port

Northbound / Split

17:00.0

11

em2

1 GbE Port 1 (Left)

MGMT/IPMI

12

em3

1 GbE Port 2

 (*MGMT)

13

em5

1 GbE Port 4 (Right)

TECH

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).


Dell IceLake CBox with dual CX6 or CX6 + CX7 NIC in IB mode, Multi-homed ETH + IB

⚠️ Warning

Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.

Dell IceLake CBox with dual CX6 or CX6 + CX7

Dell IceLake CBox

Number

Name

Port Location

Function

PCIe B:D.F

1

CNode 1

2

CNode 2

3

CNode 3

4

CNode 4

5

PSU 1

6

PSU 2

7

ib2

Right Card – Left Port

Internal

31:00.1

8

ib1

Right Card – Right Port

Internal

31:00.0

9

p1p2

Left Card – Left Port

Northbound / Split

17:00.1

10

ib0

Left Card – Right Port

Northbound / Split

17:00.0

11

em2

1 GbE Port 1 (Left)

MGMT/IPMI

12

em3

1 GbE Port 2

 (*MGMT)

13

em5

1 GbE Port 4 (Right)

TECH

*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (ens8f1).


ℹ️ Note

Using the Reverse NIC functionality together with Multi-home is supported, but has extremely limited use cases.  Thus it is not documented here.