⚠️ Warning
Networking is configured on a per-CNode basis, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a particular CNode, please contact VAST Support for assistance.
Dell IceLake CBox with Single CX6 NIC in ETH Mode

Dell IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | p2p2 | Right Card – Left Port | Unified | 31:00.1 |
8 | p2p1 | Right Card – Right Port | Unified | 31:00.0 |
9 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
10 | em3 | 1 GbE Port 2 | (*MGMT) | |
11 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (em3).
Dell IceLake CBox with Dual CX6 in ETH + ETH mode

Dell IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | p2p2 | Right Card – Left Port | Internal | 31:00.1 |
8 | p2p1 | Right Card – Right Port | Internal | 31:00.0 |
9 | p1p2 | Left Card – Left Port | Northbound / Split | 17:00.1 |
10 | p1p1 | Left Card – Right Port | Northbound / Split | 17:00.0 |
11 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
12 | em3 | 1 GbE Port 2 | (*MGMT) | |
13 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (em3).
Dell IceLake CBox with Dual CX6 NIC in ETH Mode with “Skip NIC - External” enabled
⚠️ Warning
Since this is a per-CNode setting, it is possible for a chassis to have CNodes with differing configurations. If you are unsure of the configuration of a CNode, please contact VAST Support for assistance.
When this flag is used, VAST instructs the auto-ports feature to disable the NIC that is typically designated for northbound traffic. This means that if you use this flag on a node with two NICs, the NIC designated for internal traffic will handle both internal and external (aka Unified) network traffic. This means the network interfaces that would typically be solely used for northbound connections are effectively disabled. This flag is not valid on a single NIC CNode.

Dell IceLake CBox | ||||
|---|---|---|---|---|
Number | Name | Port Location | Function | PCIe B:D.F |
1 | CNode 1 | |||
2 | CNode 2 | |||
3 | CNode 3 | |||
4 | CNode 4 | |||
5 | PSU 1 | |||
6 | PSU 2 | |||
7 | p2p2 | Right Card – Left Port | Unified | 31:00.1 |
8 | p2p1 | Right Card – Right Port | Unified | 31:00.0 |
9 | p1p2 | Left Card – Left Port | Disabled | 17:00.1 |
10 | p1p1 | Left Card – Right Port | Disabled | 17:00.0 |
11 | em2 | 1 GbE Port 1 (Left) | MGMT/IPMI | |
12 | em3 | 1 GbE Port 2 | (*MGMT) | |
13 | em5 | 1 GbE Port 4 (Right) | TECH | |
*in B2B IPMI configuration the MGMT port is moved to 1GbE port 2 (em3).
ℹ️ Note
The Dell IceLake Platform supports the Skip NIC - Internal option, but it has limited use cases and is not documented here.
ℹ️ Note
The Dell IceLake Platform supports the Reverse NICs option, but it has limited use cases and is not documented here.